ContraX-Flue Oxygen Analyzer-ZR-C101

A flue oxygen analyzer is an industrial device that measures leftover oxygen in exhaust and flue gases. It helps check combustion efficiency in boilers, furnaces, and kilns, allowing operators to adjust fuel-to-air ratios, save fuel, and reduce harmful emissio

SKU:CS0011
  • ลักษณะพิเศษ
  • Specification
  • Download
  • OLED Active Display – Bright and clear display for easy operation and convenient data viewing.
  • High-Precision Zirconia Sensor – Ensures accurate oxygen measurement with fast response and minimal drift.
  • Anti-Corrosion Sensor Coating – The flue gas contact surface can be coated to resist corrosion and extend service life.
  • High-Temperature Alloy Probe – The oxygen probe, made of high-temperature alloy steel, can be directly inserted into furnaces up to 650°C.
  • PID Automatic Temperature Control – Rapid and precise temperature adjustment minimizes external environmental influence.
  • Self-Diagnosis Function – Detects system errors automatically, improving debugging efficiency and device protection.
  • Multi-Error Alarm System – Provides multiple error alerts to enhance safety and reliability.
  • Data Logging Capability – Stores up to 5,000 records of historical data for easy access and analysis.
  • Multi-Point Calibration – Supports fractional linear calibration for highly accurate oxygen measurement across the full range.
  • IP65 Protection Rating – Ensures excellent dustproof and waterproof performance (except probe front area).
  • Configurable Analog Output – User adjustable 4-20 mA (default) or 0-10 V output range for higher precision signal control.
  • RS232 (default) or RS485 – communication port allows one-way or two-way data exchange with computers or control systems.

Measurement Principle: Zirconia (ZrO₂)

Display Model: 128×64 matrix dot OLED

Measurement Range: 0.01%~25.00% O2

Measurement Accuracy: < ±1.0% FS

Resolution: 0.01%

Repeatability: < ±0.5% FS

Stability: < ±1.0% FS

Response Time: T90 ≤ 5S

Output Port: 4-20 mADC (default) or 0-l0 VDC

  • (Non-isolated output, 4-20 mA load resistance < 1 KΩ, 0-10 V load resistance > 10 KΩ)
  • 2 ways of programmable alarm output (Dry contact type, maximum load 220V/2A)

Communication Port: RS232 (default) or RS485

Power Supply: AC220V ±10% 50/60Hz, power dissipation < 5VA

Instrument Operation Temperature: -10°C~+50°C

Probe Operation Temperature: Normal type 0~200°C, high temperature (type 0~400°C, special type 0~650°C)

Calibration Method: Online calibration

Holt-Cutting Size: < D70mm ~ < D90mm

Connecting Cable: 5 meters (standard)

Probe Length: Standard length 1110mm, (other length is customizable ≤1.5m)

Sensor Service Life: > 5 years (under normal conditions of use)

Installation Method: Wall mounting

ต้องการความช่วยเหลือด้านใด?

บริการลูกค้า

+66 (0) 2 021 2879

ศูนย์บริการ

+66 (0) 2 021 2879

ติดต่อด้านสิ่งแวดล้อม

+66 (0) 2 021 2879

อีเมล

Your cart

No products in the cart.