{"id":22572,"date":"2021-03-31T06:50:10","date_gmt":"2021-03-31T06:50:10","guid":{"rendered":"https:\/\/contrologic.co.th\/web\/products\/uncategorized\/field-device-coupler-series-9410\/"},"modified":"2021-03-31T06:50:10","modified_gmt":"2021-03-31T06:50:10","slug":"field-device-coupler-series-9410","status":"publish","type":"product","link":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/","title":{"rendered":"FIELD DEVICE COUPLER SERIES 9410"},"content":{"rendered":"<p>9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents.<\/p>\n<p>&#8211; For connecting 4, 8 or 12 fieldbus devices in Zone 2<br \/>\n&#8211; Ex ec or ic spurs<br \/>\n&#8211; Operated using High Power Trunk concept<br \/>\n&#8211; Reduced start-up current thanks to power management and short-circuit limiting with disconnection<\/p>\n","protected":false},"excerpt":{"rendered":"<p>9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents.<\/p>\n<p>&#8211; For connecting 4, 8 or 12 fieldbus devices in Zone 2<br \/>\n&#8211; Ex ec or ic spurs<br \/>\n&#8211; Operated using High Power Trunk concept<br \/>\n&#8211; Reduced start-up current thanks to power management and short-circuit limiting with disconnection<\/p>\n","protected":false},"featured_media":18323,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_cat":[949],"product_tag":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>FIELD DEVICE COUPLER SERIES 9410 - Contrologic<\/title>\n<meta name=\"description\" content=\"9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents. - For connecting 4, 8 or 12 fieldbus devices in Zone 2 - Ex ec or ic spurs - Operated using High Power Trunk concept - Reduced start-up current thanks to power management and short-circuit limiting with disconnection\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FIELD DEVICE COUPLER SERIES 9410 - Contrologic\" \/>\n<meta property=\"og:description\" content=\"9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents. - For connecting 4, 8 or 12 fieldbus devices in Zone 2 - Ex ec or ic spurs - Operated using High Power Trunk concept - Reduced start-up current thanks to power management and short-circuit limiting with disconnection\" \/>\n<meta property=\"og:url\" content=\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/\" \/>\n<meta property=\"og:site_name\" content=\"Contrologic\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/contrologic.co.th\" \/>\n<meta property=\"og:image\" content=\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"666\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/\",\"url\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/\",\"name\":\"FIELD DEVICE COUPLER SERIES 9410 - Contrologic\",\"isPartOf\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg\",\"datePublished\":\"2021-03-31T06:50:10+00:00\",\"dateModified\":\"2021-03-31T06:50:10+00:00\",\"description\":\"9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents. - For connecting 4, 8 or 12 fieldbus devices in Zone 2 - Ex ec or ic spurs - Operated using High Power Trunk concept - Reduced start-up current thanks to power management and short-circuit limiting with disconnection\",\"breadcrumb\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#primaryimage\",\"url\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg\",\"contentUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg\",\"width\":1000,\"height\":666},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/contrologic.co.th\/web\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/contrologic.co.th\/web\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"FIELD DEVICE COUPLER SERIES 9410\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#website\",\"url\":\"https:\/\/contrologic.co.th\/web\/\",\"name\":\"Contrologic\",\"description\":\"Solution provider over 30 years\",\"publisher\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/contrologic.co.th\/web\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#organization\",\"name\":\"contrologic\",\"url\":\"https:\/\/contrologic.co.th\/web\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png\",\"contentUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png\",\"width\":228,\"height\":133,\"caption\":\"contrologic\"},\"image\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/contrologic.co.th\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FIELD DEVICE COUPLER SERIES 9410 - Contrologic","description":"9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents. - For connecting 4, 8 or 12 fieldbus devices in Zone 2 - Ex ec or ic spurs - Operated using High Power Trunk concept - Reduced start-up current thanks to power management and short-circuit limiting with disconnection","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/","og_locale":"en_US","og_type":"article","og_title":"FIELD DEVICE COUPLER SERIES 9410 - Contrologic","og_description":"9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents. - For connecting 4, 8 or 12 fieldbus devices in Zone 2 - Ex ec or ic spurs - Operated using High Power Trunk concept - Reduced start-up current thanks to power management and short-circuit limiting with disconnection","og_url":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/","og_site_name":"Contrologic","article_publisher":"https:\/\/www.facebook.com\/contrologic.co.th","og_image":[{"width":1000,"height":666,"url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/","url":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/","name":"FIELD DEVICE COUPLER SERIES 9410 - Contrologic","isPartOf":{"@id":"https:\/\/contrologic.co.th\/web\/#website"},"primaryImageOfPage":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#primaryimage"},"image":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#primaryimage"},"thumbnailUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg","datePublished":"2021-03-31T06:50:10+00:00","dateModified":"2021-03-31T06:50:10+00:00","description":"9410 series Ex n field device couplers for Zone 2 can be used for interference-free connection of up to 12 FOUNDATION Fieldbus H1 or PROFIBUS PA field devices on the High Power Trunk. The spurs with type of protection ec or ic can be used for fieldbus devices in Zones 2 (ic, ec) and 1 (d, q, m) and are protected by a short-circuit limiting function. The integrated power management minimises start-up and short-circuit currents. - For connecting 4, 8 or 12 fieldbus devices in Zone 2 - Ex ec or ic spurs - Operated using High Power Trunk concept - Reduced start-up current thanks to power management and short-circuit limiting with disconnection","breadcrumb":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#primaryimage","url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg","contentUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0298.jpg","width":1000,"height":666},{"@type":"BreadcrumbList","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/field-device-coupler-series-9410\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/contrologic.co.th\/web\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/contrologic.co.th\/web\/products\/"},{"@type":"ListItem","position":3,"name":"FIELD DEVICE COUPLER SERIES 9410"}]},{"@type":"WebSite","@id":"https:\/\/contrologic.co.th\/web\/#website","url":"https:\/\/contrologic.co.th\/web\/","name":"Contrologic","description":"Solution provider over 30 years","publisher":{"@id":"https:\/\/contrologic.co.th\/web\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/contrologic.co.th\/web\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/contrologic.co.th\/web\/#organization","name":"contrologic","url":"https:\/\/contrologic.co.th\/web\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/","url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png","contentUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png","width":228,"height":133,"caption":"contrologic"},"image":{"@id":"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/contrologic.co.th"]}]}},"_links":{"self":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product\/22572"}],"collection":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/comments?post=22572"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/media\/18323"}],"wp:attachment":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/media?parent=22572"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product_cat?post=22572"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product_tag?post=22572"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}