{"id":22607,"date":"2021-03-31T06:47:51","date_gmt":"2021-03-31T06:47:51","guid":{"rendered":"https:\/\/contrologic.co.th\/web\/products\/uncategorized\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/"},"modified":"2021-03-31T06:47:51","modified_gmt":"2021-03-31T06:47:51","slug":"digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72","status":"publish","type":"product","link":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/","title":{"rendered":"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72"},"content":{"rendered":"<p>9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting.<\/p>\n<p>&#8211; 4 channels for I.S. hydraulic and solenoid valves up to 95 mA<br \/>\n&#8211; Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input<br \/>\n&#8211; Module hot swap in Zone 1 and Class I, Div. 2<\/p>\n","protected":false},"excerpt":{"rendered":"<p>9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting.<\/p>\n<p>&#8211; 4 channels for I.S. hydraulic and solenoid valves up to 95 mA<br \/>\n&#8211; Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input<br \/>\n&#8211; Module hot swap in Zone 1 and Class I, Div. 2<\/p>\n","protected":false},"featured_media":18261,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_cat":[949],"product_tag":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72 - Contrologic<\/title>\n<meta name=\"description\" content=\"9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting. - 4 channels for I.S. hydraulic and solenoid valves up to 95 mA - Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input - Module hot swap in Zone 1 and Class I, Div. 2\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72 - Contrologic\" \/>\n<meta property=\"og:description\" content=\"9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting. - 4 channels for I.S. hydraulic and solenoid valves up to 95 mA - Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input - Module hot swap in Zone 1 and Class I, Div. 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/\" \/>\n<meta property=\"og:site_name\" content=\"Contrologic\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/contrologic.co.th\" \/>\n<meta property=\"og:image\" content=\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/\",\"url\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/\",\"name\":\"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72 - Contrologic\",\"isPartOf\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg\",\"datePublished\":\"2021-03-31T06:47:51+00:00\",\"dateModified\":\"2021-03-31T06:47:51+00:00\",\"description\":\"9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting. - 4 channels for I.S. hydraulic and solenoid valves up to 95 mA - Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input - Module hot swap in Zone 1 and Class I, Div. 2\",\"breadcrumb\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#primaryimage\",\"url\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg\",\"contentUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg\",\"width\":1000,\"height\":667},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/contrologic.co.th\/web\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/contrologic.co.th\/web\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#website\",\"url\":\"https:\/\/contrologic.co.th\/web\/\",\"name\":\"Contrologic\",\"description\":\"Solution provider over 30 years\",\"publisher\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/contrologic.co.th\/web\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#organization\",\"name\":\"contrologic\",\"url\":\"https:\/\/contrologic.co.th\/web\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png\",\"contentUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png\",\"width\":228,\"height\":133,\"caption\":\"contrologic\"},\"image\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/contrologic.co.th\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72 - Contrologic","description":"9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting. - 4 channels for I.S. hydraulic and solenoid valves up to 95 mA - Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input - Module hot swap in Zone 1 and Class I, Div. 2","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/","og_locale":"en_US","og_type":"article","og_title":"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72 - Contrologic","og_description":"9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting. - 4 channels for I.S. hydraulic and solenoid valves up to 95 mA - Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input - Module hot swap in Zone 1 and Class I, Div. 2","og_url":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/","og_site_name":"Contrologic","article_publisher":"https:\/\/www.facebook.com\/contrologic.co.th","og_image":[{"width":1000,"height":667,"url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/","url":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/","name":"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72 - Contrologic","isPartOf":{"@id":"https:\/\/contrologic.co.th\/web\/#website"},"primaryImageOfPage":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#primaryimage"},"image":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#primaryimage"},"thumbnailUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg","datePublished":"2021-03-31T06:47:51+00:00","dateModified":"2021-03-31T06:47:51+00:00","description":"9475\/32-04-72 series digital output modules for Zone 1 and Class I, Div. 2 have four channels for actuating hydraulic and solenoid valves or indicator lamps. An additional I.S. control input is suitable for safe output shutdown up to SIL 2. All outputs are short-circuit proof, galvanically isolated from the system and individually monitored to check for wire breakage\/short-circuiting. - 4 channels for I.S. hydraulic and solenoid valves up to 95 mA - Ex ib outputs with line fault monitoring and LED error and status indication for each channel plus SIL 2 plant-Stop input - Module hot swap in Zone 1 and Class I, Div. 2","breadcrumb":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#primaryimage","url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg","contentUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0267.jpg","width":1000,"height":667},{"@type":"BreadcrumbList","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/digital-output-module-4-channel-version-for-zone-1-class-i-div-2-series-9475-32-04-72\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/contrologic.co.th\/web\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/contrologic.co.th\/web\/products\/"},{"@type":"ListItem","position":3,"name":"DIGITAL OUTPUT MODULE 4-CHANNEL VERSION FOR ZONE 1 \/ CLASS I, DIV.2 SERIES 9475\/32-04-72"}]},{"@type":"WebSite","@id":"https:\/\/contrologic.co.th\/web\/#website","url":"https:\/\/contrologic.co.th\/web\/","name":"Contrologic","description":"Solution provider over 30 years","publisher":{"@id":"https:\/\/contrologic.co.th\/web\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/contrologic.co.th\/web\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/contrologic.co.th\/web\/#organization","name":"contrologic","url":"https:\/\/contrologic.co.th\/web\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/","url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png","contentUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png","width":228,"height":133,"caption":"contrologic"},"image":{"@id":"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/contrologic.co.th"]}]}},"_links":{"self":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product\/22607"}],"collection":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/comments?post=22607"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/media\/18261"}],"wp:attachment":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/media?parent=22607"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product_cat?post=22607"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product_tag?post=22607"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}