{"id":22625,"date":"2021-03-31T06:46:13","date_gmt":"2021-03-31T06:46:13","guid":{"rendered":"https:\/\/contrologic.co.th\/web\/products\/uncategorized\/power-module-for-zone-2-class-i-div-2-series-9445\/"},"modified":"2021-03-31T06:46:13","modified_gmt":"2021-03-31T06:46:13","slug":"power-module-for-zone-2-class-i-div-2-series-9445","status":"publish","type":"product","link":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/","title":{"rendered":"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445"},"content":{"rendered":"<p>The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached<\/p>\n<p>&#8211; 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules<br \/>\n&#8211; Redundancy of the power module with load sharing possible<br \/>\n&#8211; Integrated polarity reversal protection<br \/>\n&#8211; Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements)<br \/>\n&#8211; Support of FDT\/DTM and Webserver for integration in asset management systems<br \/>\n&#8211; Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached<\/p>\n<p>&#8211; 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules<br \/>\n&#8211; Redundancy of the power module with load sharing possible<br \/>\n&#8211; Integrated polarity reversal protection<br \/>\n&#8211; Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements)<br \/>\n&#8211; Support of FDT\/DTM and Webserver for integration in asset management systems<br \/>\n&#8211; Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)<\/p>\n","protected":false},"featured_media":18225,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_cat":[949],"product_tag":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445 - Contrologic<\/title>\n<meta name=\"description\" content=\"The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached - 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules - Redundancy of the power module with load sharing possible - Integrated polarity reversal protection - Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements) - Support of FDT\/DTM and Webserver for integration in asset management systems - Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445 - Contrologic\" \/>\n<meta property=\"og:description\" content=\"The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached - 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules - Redundancy of the power module with load sharing possible - Integrated polarity reversal protection - Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements) - Support of FDT\/DTM and Webserver for integration in asset management systems - Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/\" \/>\n<meta property=\"og:site_name\" content=\"Contrologic\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/contrologic.co.th\" \/>\n<meta property=\"og:image\" content=\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/\",\"url\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/\",\"name\":\"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445 - Contrologic\",\"isPartOf\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg\",\"datePublished\":\"2021-03-31T06:46:13+00:00\",\"dateModified\":\"2021-03-31T06:46:13+00:00\",\"description\":\"The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached - 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules - Redundancy of the power module with load sharing possible - Integrated polarity reversal protection - Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements) - Support of FDT\/DTM and Webserver for integration in asset management systems - Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)\",\"breadcrumb\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#primaryimage\",\"url\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg\",\"contentUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg\",\"width\":1000,\"height\":667},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/contrologic.co.th\/web\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/contrologic.co.th\/web\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#website\",\"url\":\"https:\/\/contrologic.co.th\/web\/\",\"name\":\"Contrologic\",\"description\":\"Solution provider over 30 years\",\"publisher\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/contrologic.co.th\/web\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#organization\",\"name\":\"contrologic\",\"url\":\"https:\/\/contrologic.co.th\/web\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png\",\"contentUrl\":\"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png\",\"width\":228,\"height\":133,\"caption\":\"contrologic\"},\"image\":{\"@id\":\"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/contrologic.co.th\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445 - Contrologic","description":"The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached - 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules - Redundancy of the power module with load sharing possible - Integrated polarity reversal protection - Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements) - Support of FDT\/DTM and Webserver for integration in asset management systems - Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/","og_locale":"en_US","og_type":"article","og_title":"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445 - Contrologic","og_description":"The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached - 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules - Redundancy of the power module with load sharing possible - Integrated polarity reversal protection - Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements) - Support of FDT\/DTM and Webserver for integration in asset management systems - Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)","og_url":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/","og_site_name":"Contrologic","article_publisher":"https:\/\/www.facebook.com\/contrologic.co.th","og_image":[{"width":1000,"height":667,"url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/","url":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/","name":"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445 - Contrologic","isPartOf":{"@id":"https:\/\/contrologic.co.th\/web\/#website"},"primaryImageOfPage":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#primaryimage"},"image":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#primaryimage"},"thumbnailUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg","datePublished":"2021-03-31T06:46:13+00:00","dateModified":"2021-03-31T06:46:13+00:00","description":"The 9445\/35 power module is used for intrinsically safe power supply to the 9442\/35 CPU and up to 16 I\/O modules. The auxiliary power connection is established using an extendable terminal with open cable end (accessories). Up to two 9445\/35 power modules can be connected to a 9496\/35 base to provide a redundant power supply for the 9442\/35 CPU and the I\/O modules. The 9445\/35 power module monitors itself and reports notifications to the control system and asset management systems when there is an overload, the ambient temperatures are too high or the end of the service life has been reached - 24 V DC supply module for IS1+ CPU modules and 16 I\/O modules - Redundancy of the power module with load sharing possible - Integrated polarity reversal protection - Error messages in accordance with NE 107 (overload, excess temperature, maintenance requirements) - Support of FDT\/DTM and Webserver for integration in asset management systems - Extended ambient temperature range -40 \u00b0C to +75 \u00b0C (-40 \u00b0F to +167 \u00b0F)","breadcrumb":{"@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#primaryimage","url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg","contentUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2021\/03\/ST0249.jpg","width":1000,"height":667},{"@type":"BreadcrumbList","@id":"https:\/\/contrologic.co.th\/web\/products\/explosion-protection-en\/automation-interfaces-and-solutions-en\/power-module-for-zone-2-class-i-div-2-series-9445\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/contrologic.co.th\/web\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/contrologic.co.th\/web\/products\/"},{"@type":"ListItem","position":3,"name":"POWER MODULE FOR ZONE 2 \/ CLASS I, DIV.2 SERIES 9445"}]},{"@type":"WebSite","@id":"https:\/\/contrologic.co.th\/web\/#website","url":"https:\/\/contrologic.co.th\/web\/","name":"Contrologic","description":"Solution provider over 30 years","publisher":{"@id":"https:\/\/contrologic.co.th\/web\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/contrologic.co.th\/web\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/contrologic.co.th\/web\/#organization","name":"contrologic","url":"https:\/\/contrologic.co.th\/web\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/","url":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png","contentUrl":"https:\/\/contrologic.co.th\/web\/wp-content\/uploads\/2024\/03\/contrologic-logo.png","width":228,"height":133,"caption":"contrologic"},"image":{"@id":"https:\/\/contrologic.co.th\/web\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/contrologic.co.th"]}]}},"_links":{"self":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product\/22625"}],"collection":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/comments?post=22625"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/media\/18225"}],"wp:attachment":[{"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/media?parent=22625"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product_cat?post=22625"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/contrologic.co.th\/web\/wp-json\/wp\/v2\/product_tag?post=22625"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}