Vaisala K‑PATENTS® Process Refractometer PR-23-G
In-lineLiquid concentration or density measurement for process control in chemical and general industry applications
Vaisala K-PATENTS Process refractometer PR-23-G is designed for measuring theLiquid concentration and density in a wide range of chemicals, fibers, plastics, salts and sodium components. This model is also suited for Brix measurement of sugar solutions in harsh sugar industry conditions.
The PR-23-G masters highly accurate measuring technology in demanding process control applications where conventional density equipment may struggle due to undissolved solids or bubbles in the process stream. The instrument installs directly into the process pipe or vessel and provides a continuous 4-20 mA or digital measurement signal for real-time process control.
The refractometer system consists of a probe refractometer PR-23-GP or a compact refractometer PR-23-GC and an Indicating transmitter.
– Probe process refractometer PR-23-GP sensor comes with flange or clamp connection for the large pipe size and vessel installations.
– Compact process refractometer PR-23-GC sensor is intended for the small pipeline and bypass line applications. It is installed in the process either directly in a pipe elbow by a Sandvik coupling connection or in a straight pipe via a Wafer flow cell or a Pipe flow cell.
The refractometer system features dual connectivity, i.e. one transmitter can operate two sensors. A second sensor can be easily integrated later.
The measurement range covers 0-100 % by weight. The accuracy is typically ±0.1 % b.w. and the measurement is automatically temperature compensated. Low and high concentration alarms can be configured.
Each sensor is provided with a calibration certificate comparing a set of standardLiquids to the actual sensor output. The calibration and accuracy can be verified on-site with the certified Refractive IndexLiquids.
Approvals
– ATEX approved for Zones 0 and 1, area classification ATEX II 1G Ex ia IIC T4 (only Intrinsically safe PR-23-GP-IA with single sensor transmitter STR).
– ATEX approved for Zone II, area classification EX II 3 G EEx nA II T4.
– CSA certified for Class I, Div. 2, Groups A, B, C and D, T4.
– FM approved for Class I, Div. 2, Groups A, B, C and D, T6.
– cCSAus certified for Electrical Safety, Sensor: Class I, Pollution Deg. 3; Transmitter: Class I, Pollution Deg. 2; Installation Cat. II.
- Features
- Specification
- Download
In-lineLiquid concentration or density measurement for process control in chemical and general industry applications
Vaisala K-PATENTS Process refractometer PR-23-G is designed for measuring theLiquid concentration and density in a wide range of chemicals, fibers, plastics, salts and sodium components. This model is also suited for Brix measurement of sugar solutions in harsh sugar industry conditions.
The PR-23-G masters highly accurate measuring technology in demanding process control applications where conventional density equipment may struggle due to undissolved solids or bubbles in the process stream. The instrument installs directly into the process pipe or vessel and provides a continuous 4-20 mA or digital measurement signal for real-time process control.
The refractometer system consists of a probe refractometer PR-23-GP or a compact refractometer PR-23-GC and an Indicating transmitter.
– Probe process refractometer PR-23-GP sensor comes with flange or clamp connection for the large pipe size and vessel installations.
– Compact process refractometer PR-23-GC sensor is intended for the small pipeline and bypass line applications. It is installed in the process either directly in a pipe elbow by a Sandvik coupling connection or in a straight pipe via a Wafer flow cell or a Pipe flow cell.
The refractometer system features dual connectivity, i.e. one transmitter can operate two sensors. A second sensor can be easily integrated later.
The measurement range covers 0-100 % by weight. The accuracy is typically ±0.1 % b.w. and the measurement is automatically temperature compensated. Low and high concentration alarms can be configured.
Each sensor is provided with a calibration certificate comparing a set of standardLiquids to the actual sensor output. The calibration and accuracy can be verified on-site with the certified Refractive IndexLiquids.
Approvals
– ATEX approved for Zones 0 and 1, area classification ATEX II 1G Ex ia IIC T4 (only Intrinsically safe PR-23-GP-IA with single sensor transmitter STR).
– ATEX approved for Zone II, area classification EX II 3 G EEx nA II T4.
– CSA certified for Class I, Div. 2, Groups A, B, C and D, T4.
– FM approved for Class I, Div. 2, Groups A, B, C and D, T6.
– cCSAus certified for Electrical Safety, Sensor: Class I, Pollution Deg. 3; Transmitter: Class I, Pollution Deg. 2; Installation Cat. II.